GaN etch rates as a function of ICP source power in an ICP-generated BCl3/Cl2/Ar plasma at 32 sccm Cl2, 8 sccm BCl3, 5 sccm Ar, -250 V dc bias, 2 mTorr pressure and 10°C electrode temperature.