GaN etch rates as a function of pressure in an ICP-generated BCl3/Cl2/Ar plasma at 32 sccm Cl2, 8 sccm BCl5, 5 sccm Ar, 500 W IPC source power, dc-bias -150 V and 10°C electrode temperature.
top text Figure 4 Figure 6 endnotes
© 2000 The Materials Research Society